1)
Time Limit
The development hereby permitted shall be begun before the expiration of three years from the date of this permission.
Reason - As required by Section 91 of the Town and Country Planning Act 1990, to avoid the accumulation of unexercised Planning Permissions.
2)
Compliance with approved drawings
The development shall not be carried out except in complete accordance with the details shown on submitted plans
Reason - The details are material to the acceptability of the proposals, and to ensure accordance with the development plan.
3)
Submission of details
No development shall commence until detailed drawings, assessment details or samples of materials as appropriate, in respect of the following, have been submitted to and approved in writing by the local planning authority and the works shall not be carried out other than in accordance with the details so approved and shall thereafter be so maintained:
Detailed section drawing (1:10) of the retractable roof, including a sample of glazing. The details shall also include measures to reduce light spill.
Details of the proposed opening/closing mechanism for the new retractable roof, including details to demonstrate any resultant noise from its operation. The details shall demonstrate that opening/closing the roof would generate an acceptable noise impact in relation to existing background noise levels, either by the mechanism itself and/or appropriate mitigation measures.
Reason - In order to preserve the character and appearance of the building, terrace group and wider Pembridge Conservation Area and safeguard the existing living conditions of near neighbours, in accordance with policies CL3, CL5, CE6 and CL6 of the Local Plan 2019. It is necessary for the condition to be on the basis that 'No development shall commence until' as compliance with the requirements of the condition at a later time would result in unacceptable harm contrary to the policies of the Development Plan.
4)
Noise from building services plant and vents
Noise emitted by the plant, when operating concurrently or in individually, shall not increase the lowest existing measured background LA90(15min) level measured or predicted at 1.0m from the nearest residential window and/or at a height of 1.2m above any adjacent residential garden, terrace, balcony or patio at any time when the plant is operating. The plant shall be serviced regularly in accordance with manufacturer's instructions and as necessary to ensure that the requirements of the condition are maintained. If at any time the plant is unable to comply with this Condition, they shall be switched off and not used again until it is able to comply.
Reason - To prevent any significant disturbance to residents of nearby properties and comply with development plan policies, in particular policy CL5 of the Local Plan 2019.
5)
Anti-vibration mounts for extraction equipment
All plant and equipment shall be supported on adequate proprietary anti-vibration mounts as necessary to prevent the structural transmission of vibration and regenerated noise within adjacent or adjoining premises, and these shall be so maintained thereafter. If at any time the plant is unable to comply with this Condition, it shall be switched off and not used again until it is able to comply.
Reason - To prevent any significant disturbance to residents of nearby properties and comply with development plan policies, in particular policy CL5 of the Local Plan 2019.
6)
Acoustic Report - Compliance
In order to comply with condition 3, the noise mitigation measures as specified in the Noise assessment (prepared by RBA Acoustics dated 30 January 2024 ref: 12971.RP01.AAR.8), shall be adopted and implemented in full. A post installation assessment shall be submitted to and approved in writing show compliance with condition 3.
Reason - To prevent any significant disturbance to residents of nearby properties and comply with development plan policies, in particular policy CL5 of the Local Plan 2019.
7)
Artificial Lighting - Details
Prior to occupation of the development, details of external artificial lighting shall be submitted to and approved in writing by the Local Planning Authority. The details should include lighting contours to demonstrate that the vertical illumination of neighbouring premises is in accordance with the recommendations of the Institution of Lighting Professionals in the 'Guidance Note 1 for the reduction of obtrusive light 2021'. Details should also include measures to minimise use of lighting and prevent glare and sky glow by correctly using, locating, aiming and shielding luminaires. The approved details shall be implemented prior to occupation of the development and shall be maintained.
Reason - To prevent any significant disturbance to residents of nearby properties and comply with development plan policies, in particular policy CL5 of the Local Plan 2019.
8)
Garden Terrace Management Policy
Except as required by Condition 11, the development hereby approved, shall be used in accordance with details set out in the 'Garden Terrace Management Policy to be used by all staff', received by the Local Planning Authority on 01 February 2024. The use of the garden shall be carried out in accordance with the measures set out within this policy and maintained for the lifetime of the development.
Reason - To prevent any significant disturbance to residents of nearby properties and comply with development plan policies, in particular policy CL5 of the Local Plan 2019.
9)
Arboricultural Impact Assessment - Compliance
The development shall be carried out in accordance with the approved Arboricultural Impact Assessment, prepared by MDJ Trees dated January 2024, and shall be so maintained.
Reason - To ensure the proposals have an acceptable impact on trees in the Borough, in accordance with policy CR6 of the Local Plan 2019.
10)
Sustainable Urban Drainage System (SuDS) (for major and minor applications - implementation)
During construction of the development hereby permitted the submitted Flood Risk Assessment (FRA) and Sustainable Urban Drainage System (SuDS), prepared by Create Consulting Engineers Ltd. (ref. JE/VL/P23-2986/01 Rev C) dated October 2023, shall be fully implemented and maintained thereafter.
Reason - To reduce flood risk and to contribute to sustainability in accordance with policy CE2 of the Local Plan 2019.
11)
Use of outdoor area
No customers shall use the outdoor areas at the rear of the premises, including the rear balcony and area of retractable roof, between the hours of 18:00 and 10:00 the following day on Mondays to Sundays and public holidays, and between which hours all windows and external doors to these areas shall be kept closed at all times except when required for the incidental entry or exit of goods
Reason - To safeguard the existing living conditions of neighbouring residents in accordance with Policies CL5 and CE6 of the Local Plan 2019.